Paper Number
EM7 My Program
Session
New Advances in Rheometry: Experimental and Modelling Methods
Title
QL-LAOS experiments with shear-thickening suspensions
Presentation Date and Time
15 April 2025 (Tuesday) 11:40
Track / Room
Track 3 / Rhône 4
Authors
- Canazas Rodriguez, José C. (Pontifícia Universidade Católica-RJ, Mechanical Engineering)
- Fernández-Díaz, Edgardo (University of Málaga, Applied Physics II)
- de Souza Mendes, Paulo R. (Pontificia Universidade Católica de Rio de Janeiro, Mechanical engineering)
- Rubio-Hernández, Francisco J. (University of Málaga, Applied Physics II)
- Thompson, Roney L. (COPPE-UFRJ, Mechanical Engineering)
- Naccache, Monica F. (Pontificia Universidade Catolica do Rio de Janeiro, Department of Mechanical Engineering)
Author and Affiliation Lines
José C. Canazas Rodriguez1, Edgardo Fernández-Díaz2, Paulo R. de Souza Mendes1, Francisco J. Rubio-Hernández2, Roney L. Thompson3 and Monica F. Naccache1
1Mechanical engineering, Pontificia Universidade Católica de Rio de Janeiro, Rio de Janeiro, RJ 22260-140, Brazil; 2Applied Physics II, University of Málaga, Málaga, Málaga, Spain; 3Mechanical Engineering, COPPE-UFRJ, Rio de Janeiro, RJ, Brazil
Speaker / Presenter
de Souza Mendes, Paulo R.
Text of Abstract
We conducted large-amplitude oscillatory shear (LAOS) measurements to investigate the viscoelastic properties of a suspension of fumed silica in polypropylene glycol. The experiments were performed using a strain-controlled rheometer (ARES-G2, TA Instruments) equipped with a Couette geometry. A wide range of strain amplitudes and frequencies was explored to identify the quasilinear regime (QL-LAOS). An important feature of the rheometer is the torque transducer, installed on the stationary shaft connected to the inner cylinder of the Couette geometry, which eliminates contamination of the torque signal by instrument inertia. This design enables precise measurements at simultaneously high frequencies and amplitudes. The QL-LAOS regime offers a significant advantage for data analysis: since both the input and output signals remain sinusoidal, the storage (G’) and loss (G’’) moduli, calculated by the rheometer software, retain their physical meanings from the linear viscoelastic regime. However, in the QL- LAOS regime, these moduli depend on both the frequency and stress amplitude. To validate the experimental procedure, we conducted measurements on a Newtonian standard oil. These tests revealed that at high frequencies and low amplitudes, the rheometer’s evaluation of the shear rate wave becomes imprecise, resulting in spurious data. A simple correction method was developed to address this issue, which was subsequently applied to the suspension measurements. Among the findings, it was observed that the storage and loss moduli in the QL-LAOS regime are nearly two orders of magnitude larger than those measured in the small-amplitude oscillatory shear (SAOS) regime. Notably, the ratio of the loss modulus to the storage modulus remains consistently large and essentially constant, suggesting that the elasticity of the suspension is low and does not vary significantly with changes in stress, strain, or strain rate.