Paper Number
BM26 My Program
Session
Bio-rheology and Medicine
Title
Reticulated snail mucus as a model for pulmonary mucus
Presentation Date and Time
16 April 2025 (Wednesday) 11:30
Track / Room
Track 5 / Rhône 3B
Authors
- Esteban Enjuto, Lydia (Rheonova - Laboratoire Rhéologie et Procédés)
- Mouzaoui, Mohamed (Rheonova)
- Patarin, Jérémy (Rheonova)
- Shaalan, Kawthar (Laboratoire de Rhéologie et Procedés)
- Bodiguel, Hugues (Laboratoire Rheologies et Procedes)
Author and Affiliation Lines
Lydia Esteban Enjuto1, Mohamed Mouzaoui1, Jérémy Patarin1, Kawthar Shaalan2 and Hugues Bodiguel2
1Rheonova, Grenoble, France; 2Laboratoire de Rhéologie et Procedés, Gières, France
Speaker / Presenter
Esteban Enjuto, Lydia
Text of Abstract
A mucin-based, tunable, and reproducible pulmonary mucus model is crucial for advancing research on chronic and infectious respiratory diseases. In 2024, Milian et al. proposed a reticulated snail mucus model that mimics the rheology of pulmonary mucus, enabling consistent in vitro testing of treatments. Still, further studies are needed to assess its time-dependent evolution during storage, compare its solid content to native mucus and establish robust pretests for treatment evaluation.
Dry mass and salt concentration was measured in snail mucus samples at 1.3% PEG. Rheology was performed by amplitude sweeps at 1 Hz and 37°C, with strains from 10-2 % to 104 %, immediately after preparation and weekly and monthly over 3 months, with samples stored at 4°C. Serial dilutions with isotonic saline (0.9% NaCl) were tested to determine the dilution effect.
The snail mucus model exhibited a dry mass of 3%, with 0.6% consisting of salts. In both the snail model and human sputum, salts accounted for 20% of the solid mass. The correlation between the complex modulus G* and dry mass, as reported in the literature, was confirmed in the snail model. After one month at 4°C, fungal contamination caused significant changes in rheological properties, including reduced G* and critical stress, along with increased damping factor. The formulation was reproducible, with low relative standard deviations in rheological variables. For treatment testing, vortexing at 2200 rpm for 3 minutes followed by a 24-hour incubation at 37°C ensured reproducibility.
This model and the methodology developed offers a reliable platform for in vitro therapeutic evaluation. Future studies will explore the effects of various treatments, including drug dosing, formulation, and pharmacokinetics, to further enhance therapeutic development.